Galant ac pressure question
|
|
|
| |
|
Briangillen
User
Jun 22, 2014, 5:59 AM
Post #1 of 20
(2463 views)
|
Galant ac pressure question
|
Sign In
|
|
Any advice with this ac problem on my 2004 mitsubishi galant would be appreciated. The high side pressure will hold steady at 150 but slowly drop to 100. Then the compressor will kick in and bring it back up to 150. (Low side holds steady around 45. Outside temp is 90.) But it never blows cold. Thanks in advance for the help. Brian
|
|
| |
|
Hammer Time
Ultimate Carjunky
/ Moderator
Jun 22, 2014, 6:06 AM
Post #2 of 20
(2460 views)
|
Re: Galant ac pressure question
|
Sign In
|
|
Exactly how much refrigerant is in the system? ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ We offer help in answering questions, clarifying things or giving advice but we are not a substitute for an on-site inspection by a professional.
|
|
| |
|
Briangillen
User
Jun 22, 2014, 6:29 AM
Post #3 of 20
(2452 views)
|
Re: Galant ac pressure question
|
Sign In
|
|
I put 22 oz. in.
|
|
| |
|
Hammer Time
Ultimate Carjunky
/ Moderator
Jun 22, 2014, 6:31 AM
Post #4 of 20
(2450 views)
|
Re: Galant ac pressure question
|
Sign In
|
|
Year and engine size? ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ We offer help in answering questions, clarifying things or giving advice but we are not a substitute for an on-site inspection by a professional.
|
|
| |
|
Briangillen
User
Jun 22, 2014, 6:40 AM
Post #5 of 20
(2448 views)
|
Re: Galant ac pressure question
|
Sign In
|
|
It is a 2004 with a 2.4l engine.
|
|
| |
|
Hammer Time
Ultimate Carjunky
/ Moderator
Jun 22, 2014, 7:08 AM
Post #6 of 20
(2446 views)
|
Re: Galant ac pressure question
|
Sign In
|
|
OK, since you have the correct charge we can analyze the pressure problem. What it's telling me is that there is a restriction in the system. You can verify this by feeling the temp of the liquid line at idle. It should be warm to the touch but if you feel no heat at all, that tells you there is no refrigerant moving. What I usually do in that case is replace the dryer and expansion valve and that usually resolves the issue. ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ We offer help in answering questions, clarifying things or giving advice but we are not a substitute for an on-site inspection by a professional.
|
|
| |
|
Briangillen
User
Jun 22, 2014, 7:38 AM
Post #7 of 20
(2441 views)
|
Re: Galant ac pressure question
|
Sign In
|
|
Yeah, I thought there might be a restriction too. The expansion valve and drier were replaced as I have tried to find a solution to this problem. So I guess that only leaves the evaporator or the line from the compressor??? Is there any way to verify which is the problem? Thanks!
|
|
| |
|
Hammer Time
Ultimate Carjunky
/ Moderator
Jun 22, 2014, 7:43 AM
Post #8 of 20
(2437 views)
|
Re: Galant ac pressure question
|
Sign In
|
|
I have never seen an evaporator do this, although I have seen some hoses do that, sometimes a condenser. ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ We offer help in answering questions, clarifying things or giving advice but we are not a substitute for an on-site inspection by a professional.
|
|
| |
|
Discretesignals
Ultimate Carjunky
/ Moderator
Jun 22, 2014, 8:03 AM
Post #9 of 20
(2429 views)
|
Re: Galant ac pressure question
|
Sign In
|
|
Did you evacuate it before you recharged it? Since we volunteer our time and knowledge, we ask for you to please follow up when a problem is resolved.
|
|
| |
|
Briangillen
User
Jun 22, 2014, 1:38 PM
Post #10 of 20
(2410 views)
|
Re: Galant ac pressure question
|
Sign In
|
|
Yeah it was evacuated before the expansion valve was installed.
|
|
| |
|
Discretesignals
Ultimate Carjunky
/ Moderator
Jun 22, 2014, 1:51 PM
Post #11 of 20
(2408 views)
|
Re: Galant ac pressure question
|
Sign In
|
|
Was it evacuated after you installed the valve before you recharged it? Since we volunteer our time and knowledge, we ask for you to please follow up when a problem is resolved.
|
|
| |
|
Briangillen
User
Jun 22, 2014, 2:10 PM
Post #12 of 20
(2405 views)
|
Re: Galant ac pressure question
|
Sign In
|
|
No, not after the expansion valve was replaced.
|
|
| |
|
Discretesignals
Ultimate Carjunky
/ Moderator
Jun 22, 2014, 2:24 PM
Post #13 of 20
(2404 views)
|
Re: Galant ac pressure question
|
Sign In
|
|
That might be your problem then. Evacuation has to be done before you recharge the system after all repairs are made to the system. If you don't evacuate, you'll have a bunch of air and moisture in the system. The moisture will ice up the expansion valve and the air will overheat the ac compressor. You need to evacuate the system for at least 40 minutes using a good vacuum pump. The system should hold vacuum with the manifold valves closed. Since we volunteer our time and knowledge, we ask for you to please follow up when a problem is resolved.
(This post was edited by Discretesignals on Jun 22, 2014, 2:24 PM)
|
|
| |
|
Briangillen
User
Jun 22, 2014, 4:40 PM
Post #14 of 20
(2397 views)
|
Re: Galant ac pressure question
|
Sign In
|
|
Okay, thanks. I going to try it and I'll let you all know how I make out. Brian
|
|
| |
|
Briangillen
User
Jun 25, 2014, 12:55 AM
Post #15 of 20
(2365 views)
|
Re: Galant ac pressure question
|
Sign In
|
|
One last question before I get started. I couldn't find the exact amount of oil to add, I've heard rule of thumb is one ounce per component replaced. Anyone know the recommended amount to add? Thanks!
|
|
| |
|
Hammer Time
Ultimate Carjunky
/ Moderator
Jun 25, 2014, 1:06 AM
Post #16 of 20
(2364 views)
|
Re: Galant ac pressure question
|
Sign In
|
|
That depends on which components. What did you change? ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ We offer help in answering questions, clarifying things or giving advice but we are not a substitute for an on-site inspection by a professional.
|
|
| |
|
Briangillen
User
Jun 25, 2014, 1:46 AM
Post #17 of 20
(2361 views)
|
Re: Galant ac pressure question
|
Sign In
|
|
I just did the condenser and the dryer.
|
|
| |
|
Hammer Time
Ultimate Carjunky
/ Moderator
Jun 25, 2014, 4:33 AM
Post #18 of 20
(2350 views)
|
Re: Galant ac pressure question
|
Sign In
|
|
I would put about 3 ounces. ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ We offer help in answering questions, clarifying things or giving advice but we are not a substitute for an on-site inspection by a professional.
|
|
| |
|
Briangillen
User
Jun 29, 2014, 12:56 PM
Post #19 of 20
(2310 views)
|
Re: Galant ac pressure question
|
Sign In
|
|
Ok, changed the condenser and the drier. While I was at it I used some flush on the lines. (I disconnected them so I would send flush through the expansion valve or the compressor.) then I evacuated and recharged with 19 oz. Sadly, still no cold air. Pressure now 55/110. So frustrating!
|
|
| |
|
Hammer Time
Ultimate Carjunky
/ Moderator
Jun 29, 2014, 12:58 PM
Post #20 of 20
(2309 views)
|
Re: Galant ac pressure question
|
Sign In
|
|
If that is your idle pressures, what are they at 2000RPM? ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ We offer help in answering questions, clarifying things or giving advice but we are not a substitute for an on-site inspection by a professional.
|
|
| |
|